intel_thermal_supported
Regular
4.4
: Selective Inline ⚠️int intel_thermal_supported(struct cpuinfo_x86 *c);
Collision: Unique Static
Inline: Selective
Transformation: False
Instances:
In arch/x86/kernel/cpu/mcheck/therm_throt.c (ffffffff81049800)
Location: arch/x86/kernel/cpu/mcheck/therm_throt.c:452
Inline: True
Direct callers:
- arch/x86/kernel/cpu/mcheck/therm_throt.c:mcheck_intel_therm_init
- arch/x86/kernel/cpu/mcheck/therm_throt.c:intel_init_thermal
Symbols:
ffffffff81049800-ffffffff81049830: intel_thermal_supported (STB_LOCAL)
4.8
: Selective Inline ⚠️int intel_thermal_supported(struct cpuinfo_x86 *c);
Collision: Unique Static
Inline: Selective
Transformation: False
Instances:
In arch/x86/kernel/cpu/mcheck/therm_throt.c (ffffffff810499c0)
Location: arch/x86/kernel/cpu/mcheck/therm_throt.c:451
Inline: True
Direct callers:
- arch/x86/kernel/cpu/mcheck/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mcheck/therm_throt.c:mcheck_intel_therm_init
Symbols:
ffffffff810499c0-ffffffff810499f0: intel_thermal_supported (STB_LOCAL)
4.10
: Selective Inline ⚠️int intel_thermal_supported(struct cpuinfo_x86 *c);
Collision: Unique Static
Inline: Selective
Transformation: False
Instances:
In arch/x86/kernel/cpu/mcheck/therm_throt.c (ffffffff8104bdc0)
Location: arch/x86/kernel/cpu/mcheck/therm_throt.c:424
Inline: True
Direct callers:
- arch/x86/kernel/cpu/mcheck/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mcheck/therm_throt.c:mcheck_intel_therm_init
Symbols:
ffffffff8104bdc0-ffffffff8104bdf0: intel_thermal_supported (STB_LOCAL)
4.13
: Selective Inline ⚠️int intel_thermal_supported(struct cpuinfo_x86 *c);
Collision: Unique Static
Inline: Selective
Transformation: False
Instances:
In arch/x86/kernel/cpu/mcheck/therm_throt.c (ffffffff8104b530)
Location: arch/x86/kernel/cpu/mcheck/therm_throt.c:418
Inline: True
Direct callers:
- arch/x86/kernel/cpu/mcheck/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mcheck/therm_throt.c:mcheck_intel_therm_init
Symbols:
ffffffff8104b530-ffffffff8104b560: intel_thermal_supported (STB_LOCAL)
4.15
: Selective Inline ⚠️int intel_thermal_supported(struct cpuinfo_x86 *c);
Collision: Unique Static
Inline: Selective
Transformation: False
Instances:
In arch/x86/kernel/cpu/mcheck/therm_throt.c (ffffffff8104ef40)
Location: arch/x86/kernel/cpu/mcheck/therm_throt.c:404
Inline: True
Direct callers:
- arch/x86/kernel/cpu/mcheck/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mcheck/therm_throt.c:mcheck_intel_therm_init
Symbols:
ffffffff8104ef40-ffffffff8104ef70: intel_thermal_supported (STB_LOCAL)
4.18
: Full Inline ⚠️Collision: Unique Static
Inline: Full
Transformation: False
Instances:
In arch/x86/kernel/cpu/mcheck/therm_throt.c (ffffffff81051c8f)
Location: arch/x86/kernel/cpu/mcheck/therm_throt.c:404
Inline: True
Inline callers:
- arch/x86/kernel/cpu/mcheck/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mcheck/therm_throt.c:mcheck_intel_therm_init
5.0
: Full Inline ⚠️Collision: Unique Static
Inline: Full
Transformation: False
Instances:
In arch/x86/kernel/cpu/mce/therm_throt.c (ffffffff8104f308)
Location: arch/x86/kernel/cpu/mce/therm_throt.c:407
Inline: True
Inline callers:
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
5.3
: Full Inline ⚠️Collision: Unique Static
Inline: Full
Transformation: False
Instances:
In arch/x86/kernel/cpu/mce/therm_throt.c (ffffffff8105242f)
Location: arch/x86/kernel/cpu/mce/therm_throt.c:408
Inline: True
Inline callers:
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
5.4
: Full Inline ⚠️Collision: Unique Static
Inline: Full
Transformation: False
Instances:
In arch/x86/kernel/cpu/mce/therm_throt.c (ffffffff81052d1f)
Location: arch/x86/kernel/cpu/mce/therm_throt.c:408
Inline: True
Inline callers:
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
5.8
: Selective Inline ⚠️int intel_thermal_supported(struct cpuinfo_x86 *c);
Collision: Unique Static
Inline: Selective
Transformation: False
Instances:
In arch/x86/kernel/cpu/mce/therm_throt.c (ffffffff81057d2f)
Location: arch/x86/kernel/cpu/mce/therm_throt.c:627
Inline: True
Inline callers:
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
Direct callers:
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
Symbols:
ffffffff81057310-ffffffff81057340: intel_thermal_supported (STB_LOCAL)
5.11
: Selective Inline ⚠️int intel_thermal_supported(struct cpuinfo_x86 *c);
Collision: Unique Static
Inline: Selective
Transformation: False
Instances:
In arch/x86/kernel/cpu/mce/therm_throt.c (ffffffff81056aaf)
Location: arch/x86/kernel/cpu/mce/therm_throt.c:627
Inline: True
Inline callers:
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
Direct callers:
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
Symbols:
ffffffff810560c0-ffffffff810560f0: intel_thermal_supported (STB_LOCAL)
5.13
: Selective Inline ⚠️int intel_thermal_supported(struct cpuinfo_x86 *c);
Collision: Unique Static
Inline: Selective
Transformation: False
Instances:
In drivers/thermal/intel/therm_throt.c (ffffffff8194746f)
Location: drivers/thermal/intel/therm_throt.c:610
Inline: True
Inline callers:
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
Direct callers:
- drivers/thermal/intel/therm_throt.c:therm_lvt_init
Symbols:
ffffffff81946b10-ffffffff81946b40: intel_thermal_supported (STB_LOCAL)
5.15
: Selective Inline ⚠️int intel_thermal_supported(struct cpuinfo_x86 *c);
Collision: Unique Static
Inline: Selective
Transformation: False
Instances:
In drivers/thermal/intel/therm_throt.c (ffffffff819ec2d3)
Location: drivers/thermal/intel/therm_throt.c:615
Inline: True
Inline callers:
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
Direct callers:
- drivers/thermal/intel/therm_throt.c:therm_lvt_init
Symbols:
ffffffff819eb5d0-ffffffff819eb600: intel_thermal_supported (STB_LOCAL)
5.19
: Selective Inline ⚠️int intel_thermal_supported(struct cpuinfo_x86 *c);
Collision: Unique Static
Inline: Selective
Transformation: False
Instances:
In drivers/thermal/intel/therm_throt.c (ffffffff81b522c3)
Location: drivers/thermal/intel/therm_throt.c:631
Inline: True
Inline callers:
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
Direct callers:
- drivers/thermal/intel/therm_throt.c:therm_lvt_init
Symbols:
ffffffff81b51580-ffffffff81b515b8: intel_thermal_supported (STB_LOCAL)
6.2
: Full Inline ⚠️Collision: Unique Static
Inline: Full
Transformation: False
Instances:
In drivers/thermal/intel/therm_throt.c (ffffffff81cea483)
Location: drivers/thermal/intel/therm_throt.c:635
Inline: True
Inline callers:
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
- drivers/thermal/intel/therm_throt.c:therm_lvt_init
- drivers/thermal/intel/therm_throt.c:therm_lvt_init
6.5
: Full Inline ⚠️Collision: Unique Static
Inline: Full
Transformation: False
Instances:
In drivers/thermal/intel/therm_throt.c (ffffffff81d52fc3)
Location: drivers/thermal/intel/therm_throt.c:691
Inline: True
Inline callers:
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
- drivers/thermal/intel/therm_throt.c:therm_lvt_init
- drivers/thermal/intel/therm_throt.c:therm_lvt_init
6.8
: Full Inline ⚠️Collision: Unique Static
Inline: Full
Transformation: False
Instances:
In drivers/thermal/intel/therm_throt.c (ffffffff81e09d23)
Location: drivers/thermal/intel/therm_throt.c:691
Inline: True
Inline callers:
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
- drivers/thermal/intel/therm_throt.c:intel_init_thermal
- drivers/thermal/intel/therm_throt.c:therm_lvt_init
- drivers/thermal/intel/therm_throt.c:therm_lvt_init
arm64
: Absent ⚠️
armhf
: Absent ⚠️
ppc64el
: Absent ⚠️
riscv64
: Absent ⚠️
aws
: Full Inline ⚠️Collision: Unique Static
Inline: Full
Transformation: False
Instances:
In arch/x86/kernel/cpu/mce/therm_throt.c (ffffffff81052e1f)
Location: arch/x86/kernel/cpu/mce/therm_throt.c:408
Inline: True
Inline callers:
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
azure
: Full Inline ⚠️Collision: Unique Static
Inline: Full
Transformation: False
Instances:
In arch/x86/kernel/cpu/mce/therm_throt.c (ffffffff8104286e)
Location: arch/x86/kernel/cpu/mce/therm_throt.c:408
Inline: True
Inline callers:
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
gcp
: Full Inline ⚠️Collision: Unique Static
Inline: Full
Transformation: False
Instances:
In arch/x86/kernel/cpu/mce/therm_throt.c (ffffffff81052ccf)
Location: arch/x86/kernel/cpu/mce/therm_throt.c:408
Inline: True
Inline callers:
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
lowlatency
: Full Inline ⚠️Collision: Unique Static
Inline: Full
Transformation: False
Instances:
In arch/x86/kernel/cpu/mce/therm_throt.c (ffffffff8105414f)
Location: arch/x86/kernel/cpu/mce/therm_throt.c:408
Inline: True
Inline callers:
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:intel_init_thermal
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
- arch/x86/kernel/cpu/mce/therm_throt.c:mcheck_intel_therm_init
Regular
4.4
and 4.8
✅
4.8
and 4.10
✅
4.10
and 4.13
✅
4.13
and 4.15
✅
5.8
and 5.11
✅
5.11
and 5.13
✅
5.13
and 5.15
✅
5.15
and 5.19
✅