inode_set_iversion
Regular
4.4
: Absent ⚠️
4.8
: Absent ⚠️
4.10
: Absent ⚠️
4.13
: Absent ⚠️
4.15
: Absent ⚠️
4.18
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff8135c43d)
Location: include/linux/iversion.h:128
Inline: True
Inline callers:
- fs/ext4/ioctl.c:ext4_ioctl
In fs/ext4/super.c (ffffffff8137dfc2)
Location: include/linux/iversion.h:128
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff813aed32)
Location: include/linux/iversion.h:128
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
5.0
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff813748aa)
Location: include/linux/iversion.h:128
Inline: True
Inline callers:
- fs/ext4/ioctl.c:ext4_ioctl
In fs/ext4/super.c (ffffffff81396867)
Location: include/linux/iversion.h:128
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff813c7f11)
Location: include/linux/iversion.h:128
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
5.3
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff8139d386)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff813c08b8)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff813f2afa)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
5.4
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff813b5df6)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff813d9c08)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff8140cabb)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
5.8
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff814017f8)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff81425f38)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff8145aa20)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
5.11
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff814141f3)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff8143d6c4)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff81476d70)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
5.13
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff8141a465)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff81443504)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff8147c7e4)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
5.15
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff8146d658)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff814971b4)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff814d3ed9)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
5.19
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff814edf26)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff81521fdb)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff81561111)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
6.2
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff81587e03)
Location: include/linux/iversion.h:147
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff815be9f0)
Location: include/linux/iversion.h:147
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff81603599)
Location: include/linux/iversion.h:147
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
6.5
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff815be683)
Location: include/linux/iversion.h:165
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff815f57ab)
Location: include/linux/iversion.h:165
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff8163b4b9)
Location: include/linux/iversion.h:165
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
6.8
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff815f743c)
Location: include/linux/iversion.h:165
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff8162e0bb)
Location: include/linux/iversion.h:165
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff81674a18)
Location: include/linux/iversion.h:165
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
arm64
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffff80001048a7d4)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffff8000104ad17c)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffff8000104ed71c)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
armhf
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (c064ca54)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (c0675f44)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (c06ab474)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
ppc64el
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (c0000000005b1bd0)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (c0000000005e5dac)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (c00000000062c548)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
riscv64
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffe000311cb2)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffe0003306e6)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffe00035dcca)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
aws
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff813ae3d6)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff813d21e8)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff8140509b)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
azure
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff8139ee66)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff813c2c68)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff813f5b1b)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
gcp
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff813abc36)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff813cf678)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff8140241b)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode
lowlatency
: Duplicate, Full Inline ⚠️Collision: Static Duplication
Inline: Full
Transformation: False
Instances:
In fs/ext4/ioctl.c (ffffffff813c05d6)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/ioctl.c:swap_inode_boot_loader
In fs/ext4/super.c (ffffffff813e4c78)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/ext4/super.c:ext4_alloc_inode
In fs/fat/inode.c (ffffffff814183eb)
Location: include/linux/iversion.h:152
Inline: True
Inline callers:
- fs/fat/inode.c:fat_fill_super
- fs/fat/inode.c:fat_build_inode